Free Sample Button Free Sample
Valve Comparison

Check Valve vs Foot Valve: Key Differences

Understand installation locations, flow direction, strainers and priming functions when choosing between inline check valves and pump-suction foot valves.

Compare Valves ↓
Backflow preventionPump primingSuction protection
Inline irrigation check valve beside a screened foot valve used on a pump suction pipe
A foot valve is a specialized check valve installed at the submerged suction inlet and normally includes a strainer.
Quick Answer

A Foot Valve Is a Check Valve Designed for a Suction Inlet

Both allow flow in one direction and close against reverse flow. The difference is application: a general check valve fits within a pipeline, while a foot valve sits at the lower end of a pump suction pipe to retain the water column and screen larger debris.

Decision factorInline check valveFoot valve
Primary rolePrevent reverse flow within an irrigation pipeline or equipment assembly.Help retain prime in a suction-lift system when the pump stops.
Typical locationPump discharge, branch line, filter/fertigation assembly or other engineered point.Submerged at the water-source end of the suction pipe.
StrainerNot normally integral; protection is selected separately where needed.Normally includes an inlet screen or basket.
Common designsSwing, spring, ball, lift, wafer or silent check.Swing or spring-style non-return element combined with a screened inlet.
Main selection riskExcess head loss, unsuitable orientation, slow closure or damaging slam.Undersized screen, air leakage, sediment blockage, poor submergence or loss of prime.
They are related, but not interchangeable in every location.

An ordinary inline check valve without a suitable screened inlet is not automatically a foot valve. A foot valve on the suction side also does not replace a discharge check valve when the pump or system design requires one.

System Location

Where Each Valve Belongs

Pipeline protection

Inline check valve

Install with the body arrow in the permitted flow direction and follow the manufacturer’s orientation requirements. On pump discharge, a correctly selected valve can prevent reverse flow toward a stopped pump. Other locations may protect filters, fertigation equipment or separate zones.

Suction-lift priming

Foot valve

Place the screened inlet below the lowest expected operating water level, above bottom sediment and far enough from walls or intake turbulence. All suction joints must remain airtight because a leaking joint or valve can let the water column fall and the pump lose prime.

Never assume the pump can run dry.

Prime the casing and suction pipe according to the pump manual. If the pump fails to prime or loses prime during startup, stop it and correct the suction-side problem before restarting.

Pump system diagram showing a foot valve at the submerged suction inlet and a check valve on the discharge pipe
Show the water source, pump, suction lift, priming point, foot valve, discharge check valve and flow arrows.
Selection Guide

Choose for Flow, Pressure and Water Quality

Connection size alone does not determine valve capacity. Compare the required flow with published head-loss data and verify the complete operating envelope.

Hydraulics

Limit pressure loss

  • Design and maximum flow
  • Cracking or opening pressure
  • Head loss at rated flow
  • Static and surge pressure
Compatibility

Match the system

  • Body and seal material
  • Water, fertilizer and chemicals
  • BSP, NPT, socket or flange
  • Horizontal or vertical orientation
Suction intake

Size the foot valve

  • Screen open area
  • Expected debris and sediment
  • Lowest operating water level
  • Inspection and cleaning access
Foot valve submerged below minimum water level with clearance above sediment and away from tank walls
Use the pump and valve manufacturers’ minimum submergence and clearance values rather than a universal distance.

Information to provide when ordering

ApplicationPump suction, pump discharge, branch isolation or equipment protection
HydraulicsFlow range, operating pressure, suction lift and acceptable pressure loss
PipeworkSize, connection standard, material and permitted valve orientation
Water sourceWell, canal, pond or tank; debris, sand, algae and seasonal level changes
MaterialsBody, spring, screen and elastomer compatibility with water and injected chemicals
Installation Checklist

Prevent Leakage, Blockage and Loss of Prime

Before startup

  1. Confirm the flow arrow and permitted orientation.
  2. Flush construction debris before fitting the valve.
  3. Support pipework independently of the pump and valve.
  4. Make every suction-side connection airtight.
  5. Submerge the foot valve at the required operating level.
  6. Prime and vent the pump according to its manual.

Routine inspection

  1. Check whether the suction line holds water after shutdown.
  2. Clean algae, leaves and sediment from the foot-valve screen.
  3. Inspect the disc, spring, hinge, seat and elastomer.
  4. Look for cracked fittings and suction-side air leaks.
  5. Record unusual pump noise, pressure or restart delay.
  6. Replace worn components with approved parts.
SymptomPossible causeFirst checks
Pump repeatedly loses primeLeaking foot valve, suction joint air leak, low water level or damaged suction pipeLeak-test the suction line, inspect the seat and confirm submergence.
Low flow or cavitation symptomsBlocked screen, undersized valve/pipe, excessive suction lift or too many fittingsStop the pump, clean the screen and verify suction design against the pump manual.
Reverse flow after shutdownDebris on the check-valve seat, worn seal, broken spring/hinge or wrong orientationIsolate and depressurize, then inspect the valve and flow arrow.
Valve slams or creates surgeUnsuitable check-valve dynamics, high reverse velocity or poor valve locationReview system transients and select closure characteristics with the system designer.
A foot-valve screen is not complete water treatment.

It blocks larger intake debris but may not protect small pump passages, filters, solenoid valves or drip emitters. Select the main filtration system for the actual water quality and downstream equipment.

Valve FAQ

Check Valve vs Foot Valve FAQs

Is a foot valve a type of check valve?

Yes. It is a non-return valve configured for the submerged end of a pump suction pipe and normally includes a strainer or screen.

Can I use a regular check valve instead of a foot valve?

Only if the pump and intake design specifically permit it and suitable inlet screening is provided. A general inline valve is not automatically designed for submerged suction service or intake debris.

Where should a foot valve be installed?

At the water-source end of the suction pipe, below the lowest expected operating water level and clear of bottom sediment, walls and intake turbulence. Follow the pump and valve manufacturers’ specified submergence and orientation.

Does a foot valve prime the pump automatically?

It helps retain the water column after the suction pipe and pump have been filled, but it does not eliminate the initial priming procedure. Never start a non-self-priming pump dry.

Why does a pump lose prime even with a foot valve?

Possible causes include debris on the valve seat, a worn seal, insufficient submergence, a cracked suction pipe or air leakage at a suction-side joint.

Should I install a check valve before or after the pump?

A foot valve may be used at the suction inlet in a suction-lift system. A separate check valve may be required on the discharge side. The correct arrangement depends on the pump instructions and complete hydraulic design.

Need Help Selecting a Non-Return Valve?